An 80-year-old woman was admitted to our institution because of shortness of breath (New York Heart Association grade III) and stable angina pectoris (Canadian Cardiovascular Society [CCS] grade II).
Two years ago, the patient had a posterior wall infarction successfully treated by percutaneous coronary intervention and stent implantation. A low-gradient aortic stenosis with an aortic valve area of 1.1 cm2 was also diagnosed but was considered to be clinically insignificant at the time.
Because of the progression of symptoms within the last 2 years, a re-evaluation of coronary and aortic valve disease was performed. Coronary angiography revealed a 1-vessel coronary disease with a patent stent in the right coronary artery without any evidence of restenosis. The left ventricular ejection fraction was only moderately impaired (55%). However, the aortic valve area, as determined invasively, had decreased to 0.5 cm2. This was confirmed by echocardiography; the cusps of the aortic valve were calcified and their motion was impaired (Supplemental Data Movie 1).
On the basis of these findings, the necessity of an aortic valve replacement was discussed. However, because the patient was anxious and refused conventional aortic valve replacement, percutaneous treatment of the aortic stenosis using the second generation of the CoreValve ReValving system (CoreValve Inc, Irvine, Calif) was proposed1 (Figure 1A). This prosthesis has an inner diameter of 23 mm and consists of a self-expanding nitinol frame, which carries 3 leaflets of porcine pericardial tissue. The upper part of the frame anchors the system in the aorta; the middle part of the prosthesis is constrained to avoid interference with the coronaries and carries the valve. The lower part of the stent exerts high radial forces (which pushed aside the calcified leaflets), avoids recoil, and is covered with pericardium to minimize paravalvular leaks.1
|
Despite the increasing use of percutaneous aortic valve replacement, little is known about ingrowths of prostheses and durability in humans.1–3 The autopsy of our patient, who unfortunately committed suicide 425 days after implantation, might give some insight with regard to the CoreValve prosthesis.
The calcified native valve was pushed aside by the CoreValve frame, and neither the native cusps nor the implanted bioprosthesis had any interference with the coronaries (Figure 2A). The bioprosthetic valve did not show any signs of morphological deterioration at autopsy (Figures 1B and 2
B). The lower part of the stent, which was covered by porcine pericardium (Figure 1A) and positioned in the left ventricular outflow tract, was completely enclosed by fibromyoblasts (Figures 1B, 3A, and 3
B). The ingrowths of the stent in the left ventricular outflow tract might explain why paravalvular leaks that are evident immediately after implantation disappear over time.1 Conversely, in the ascending aorta, only those struts of the frame that had close contact to the aortic wall were covered by endothelium (Figures 1B and 2
A). All other parts of the frame, in particular the struts at the top, which extended into the aorta, had a surface without discoloration (Figures 1B and 2
A).
|
|
| Disclosures |
|---|
|
|
|---|
| Footnotes |
|---|
| References |
|---|
|
|
|---|
2. Webb JG, Pasupati S, Humphries K, Thompson C, Altwegg L, Moss R, Sinhal A, Carere RG, Munt B, Ricci D, Ye J, Cheung A, Lichtenstein SV. Percutaneous transarterial aortic valve replacement in selected high-risk patients with aortic stenosis. Circulation. 2007; 116: 755–763.
3. Walther T, Mohr FW. Aortic valve surgery: time to be open-minded and to rethink. Eur J Cardiothorac Surg. 2007; 31: 4–6.
This article has been cited by other articles:
![]() |
S. R. Dixon, C. L. Grines, and W. W. O'Neill The year in interventional cardiology. J. Am. Coll. Cardiol., June 2, 2009; 53(22): 2080 - 2097. [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Home | Subscriptions | Archives | Feedback | Authors | Help | Circulation Journals Home | AHA Journals Home | Search Copyright © 2008 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |