Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation: Cardiovascular Interventions
Search: search_blue_button Advanced Search
Published Online
on April 21, 2009

Circulation: Cardiovascular Interventions. 2009
Published online before print April 21, 2009, doi: 10.1161/CIRCINTERVENTIONS.109.854679
A more recent version of this article appeared on June 1, 2009
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2/3/205    most recent
CIRCINTERVENTIONS.109.854679v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yokoyama, S.
Right arrow Articles by Mizuno, K.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Yokoyama, S.
Right arrow Articles by Mizuno, K.
Related Collections
Right arrow Catheter-based coronary interventions: stents

Original Article

Extended Follow-Up by Serial Angioscopic Observation for Bare-Metal Stents in Native Coronary Arteries: From Healing Response to Atherosclerotic Transformation of Neointima

Shinya Yokoyama1; Masamichi Takano2,3; Masanori Yamamoto1; Shigenobu Inami2; Shunta Sakai1; Kentaro Okamatsu1; Shinichi Okuni1; Koji Seimiya1; Daisuke Murakami1; Takayoshi Ohba1; Ryota Uemura1; Yoshihiko Seino1; Noritake Hata1 and Kyoichi Mizuno2

1 Chiba-Hokusoh Hospital, Nippon Medical School, Chiba, Japan;
2 Nippon Medical School, Tokyo, Japan

3 E-mail: takanom{at}nms.ac.jp

Background—Although coronary angiograms after bare-metal stent (BMS) implantation show late luminal narrowing beyond 4 years, the detailed changes inside the BMS have not yet been fully elucidated.

Methods and Results—Serial angiographic and angioscopic examinations were performed immediately (baseline), 6 to 12 months (first follow-up), and ≥4 years (second follow-up) after stenting without target lesion revascularization in 26 segments of 26 patients who received BMS deployment for their native coronary arteries. Angioscopic observation showed atherosclerotic yellow plaque crushed out by stent struts in 22 patients (85%) and mural thrombus in 21 patients (81%) at baseline. At first follow-up, white neointimal hyperplasia was almost completely buried inside the struts, and both yellow plaque and thrombus had decreased in comparison to the baseline (12% and 4%, respectively; P<0.001). The frequencies of yellow plaque and thrombus increased from the first to second follow-ups (58% and 31%, respectively; P<0.05). All of the yellow plaques in the second follow-up were located not exterior to the struts but protruding from the vessel wall into the lumen. Late luminal narrowing, defined as an increasing of percent diameter stenosis between the first and second follow-ups, was greater in segments with yellow plaque than in those without yellow plaque (18.4±17.3% vs. 3.6±4.2%, respectively; P=0.011).

Conclusions—This angiographic and angioscopic study suggests that white neointima of the BMS may often change into yellow plaque over an extended period of time, and atherosclerotic progression inside the BMS may contribute to late luminal narrowing.

Key Words: plaque • stents • thrombus

Author contributions: Drs Shinya Yokoyama and Masamichi Takano contributed equally to this work.




This article has been cited by other articles:


Home page
Circ Cardiovasc IntervHome page
S. Cook and P. Wenaweser
Off-Label Use and the Spectre of Drug-Eluting Stent Thrombosis
Circ Cardiovasc Interv, August 1, 2009; 2(4): 273 - 276.
[Full Text] [PDF]